NCP1207B
PWM Controller, Free Running Quasi-Resonant Current Mode
制造商:ON
产品信息
The NCP1207A/B combines a true current mode modulator and a demagnetization detector to ensure full borderline/critical Conduction Mode in any load/line conditions and minimum drain voltage switching (Quasi-Resonant operation). Due to its inherent skip cycle capability, the controller enters burst mode as soon as the power demand falls below a predetermined level. As this happens at low peak current, no audible noise can be heard. For the NCP1207A, an internal 8.0 micro s timer prevents the free-run frequency to exceed 125 kHz (therefore below the 150 kHz CISPR-22 EMI starting limit), while the skip adjustment capability lets the user select the frequency at which the burst foldback takes place. For the NCP1207B, the internal timer duration is reduced to 4.5 micro s to allow operation at higher frequencies (up to 200 kHz).
The Dynamic Self-Supply (DSS) drastically simplifies the transformer design in avoiding the use of an auxiliary winding to supply the NCP1207A/B. This feature is particularly useful in applications where the output voltage varies during operation (e.g. battery chargers). Due to its high-voltage technology, the IC is directly connected to the high-voltage DC rail. As a result, the short-circuit trip point is not dependent upon any VCC auxiliary level.
The transformer core reset detection is done through an auxiliary winding which, brought via a dedicated pin, also enables fast overvoltage Protection (OVP). Once an OVP has been detected, the IC permanently latches off.
Finally, the continuous feedback signal monitoring implemented with an overcurrent fault protection circuitry (OCP) makes the final design rugged and reliable.
The Dynamic Self-Supply (DSS) drastically simplifies the transformer design in avoiding the use of an auxiliary winding to supply the NCP1207A/B. This feature is particularly useful in applications where the output voltage varies during operation (e.g. battery chargers). Due to its high-voltage technology, the IC is directly connected to the high-voltage DC rail. As a result, the short-circuit trip point is not dependent upon any VCC auxiliary level.
The transformer core reset detection is done through an auxiliary winding which, brought via a dedicated pin, also enables fast overvoltage Protection (OVP). Once an OVP has been detected, the IC permanently latches off.
Finally, the continuous feedback signal monitoring implemented with an overcurrent fault protection circuitry (OCP) makes the final design rugged and reliable.
- Free-Running Borderline/Critical Mode Quasi-Resonant Operation
- Current-Mode with Adjustable Skip-Cycle capability
- Auto-Recovery Over Current Protection
- 500 mA Peak Current Source/Sink Capability
- Internal 1.0 ms SoftStart
- Internal 4.5 s Minimum TOFF
- Latched Over Voltage Protection
电路图、引脚图和封装图
在线购买
型号:NCP1207BDR2G
描述:-
技术资料
应用案例
博文 | 安森美图腾柱控制器NCP1680/NCP1681 应用方案选型
2022-09-07
博文 | 安森美图腾柱控制器NCP1680/NCP1681 应用方案选型
2022-09-07
泰凌微电子Thread RCP和NCP方案介绍(二)
2023-08-30
泰凌微电子Thread RCP和NCP方案介绍
2023-08-30
博文 | 安森美图腾柱控制器NCP1680/NCP1681 应用方案选型
2022-09-07
NCP1840典型应用电路
2012-05-07
NCP1072/NCP1075电源解决方案的主要特点及应用
2021-03-14
博文 | 安森美图腾柱控制器NCP1680/NCP1681 应用方案选型
2022-09-07